THE SINGLE BEST STRATEGY TO USE FOR DP50RB

The Single Best Strategy To Use For Dp50rb

The Single Best Strategy To Use For Dp50rb

Blog Article

Assistance 4D probe; figure out the probe via the ID code; switch the 4D push sign via the  electrical relay to create the 4D probe work Ordinarily. four.2.2 Primary board The most crucial board could be divided into two components: entrance-stop of the most crucial board and back-close of the leading board.

The person isn't allowed to open up the addresses and panel on the procedure, neither NOTE: unit disassemble is allowed. To make sure the program overall performance and basic safety, only Mindray engineers or engineers licensed by Mindray can carry out servicing.

Get a complete and extended watch of your anatomical composition through panoramic imaging coupled with velocity indicator and forward/backward scan potential earning scanning a lot easier, smoother and even more controllable.

Untuk memenuhi janji menyediakan perawatan kesehatan berkualitas tinggi dan efektif, Mindray terus mengembangkan kemajuan teknologi medis untuk meningkatkan kualitas perawatan pasien. Dilengkapi dengan PW Doppler dan kemampuan 3D/4D, DP-50Exp menawarkan lebih dari yang Anda harapkan.

Click Concur and Carry on to just accept cookies and go directly to the site or click More details to discover detailed descriptions of the types of cookies and select whether to accept certain cookies though on the positioning.

Mindray’s new era of black & white ultrasound method, DP-fifty Qualified, is supplied with Highly developed imaging systems enabling deeper penetration and quicker impression acquisition with larger resolution.

S. will have to provide the Department with an email handle if they have got just one. The email messages offered could possibly be utilized for official communication with the licensee. Having said that e mail addresses are general public file. If you do not want to produce a private tackle, be sure to offer the Division by having an email deal with which may be built available to the public. Please see our Chapter 455 webpage to ascertain In case you are influenced by this alteration.

Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi depth mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.

Assessing sufferers in these days’s demanding ecosystem calls for progressive engineering that enables clinicians to help make fast and self-confident diagnoses. The flexibility of your DP-fifty expands your scientific utility when helping to strengthen individual care.

five.two.3 Geometric positioning accuracy Longitudinal geometric positioning accuracy  Examination Action: Do adjustments as just how in screening the maximum depth. File the gap by 20mm Each individual phase around the longitudinal targets line utilizing the measurement caliper; Pick out the value with the greatest mistake (to 20mm), estimate the precision using the formulation beneath The measurement caliper must be positioned within the higher edge of the goal, NOTE:... Page 79 Transverse geometric positioning accuracy  Exam Move: Deal with the scan surface area in the phantom with water or couple gel, Carefully Make contact with the probe Together with the scan surface Regulate the depth, building the transverse targets to get exhibited inside the image. Change the main target level to be posited beside the transverse targets (the typical just isn't clear) Alter parameters like get, TGC, making Just about every transverse targets to become Obviously displayed. Web page eighty 5.5.two.four Blackout Region Take a look at Phase: Deal with the scan area with the phantom with drinking water or few gel, gently Get in touch with the probe Together with the scan floor Alter the depth at a reduced value, and established the focus at the closest location to the scan surface area. Reduce the worth of parameters like AP, Achieve until eventually the qualifications noise just is usually viewed. Website page 81: Software Up grade And Maintenance

The DP-50 Pro is definitely an progressive, significant-efficiency Ultrasound Process engineered that will help you get the insights you'll need. The Program’s strong engine and high-velocity processing give superb impression high quality and an entire data administration Option.

.. Page 161 The indicator on the printer Faults occur if the adapter turns orange, plus the printing printer adapter runs. Disconnect and hook up the fails. energy adapter, electrical power over the printer adapter once again, and validate whether the printing is ordinary immediately after 1 moment. Web site 163: Electrical Basic safety Inspection

Performance Test 5.5.1 Take a look at Method Resolution Detection depth Geometric Placement Accuracy Blackout space take a look at History the Test illustrations or photos five.5.2 Examination Articles The image made use of here is just for reference, stick with the image influence in the actual NOTE: problem. Requirements: Exhibit: set the contrast and brightness at the scientific software price (or perhaps the default position) Operation atmosphere: dark area, simulating the medical software ecosystem. Site seventy six In issue which the transverse resolution tests targets are horizontally exhibited, history the nominal length of two targets which can be Plainly identified. Repeat the Procedure higher than for your transverse resolution testing targets at other depths. As revealed in determine below. Axial resolution ... Web site seventy seven When utilizing the convex probe, hold the transverse resolution screening targets to notice: be shown near the midline. When using a linear probe with steer perform, usually do not turn on the steer perform when execute the transverse resolution exam. Zoom in the location wherever the targets Situated if necessary. The diameter of the goal point at a particular depth is equivalent towards the transverse resolution within the depth. Web site 78 5.

Soon after changing the CPU module, critical file have to be produced Once more based on the new MAC handle and created into HDD with the equipment. Or else, the configuration functionality in the products will likely be misplaced. Immediately after eradicating the CPU module, Eliminate panhead screws with washers (12 M3X6) fixed on the principle unit box, you will take off the board. Website page 118 Figure eight-29 Disassemble the Control Panel Assembly (one) Maintain the upper fringe of control panel assembly, and open up up the user interface. Figure eight-30 Disassemble the User interface Assembly (2) Right after removing a single countersunk head self-tapping screw PT3X10 set within the control panel and take out the plug of your keyboard and the main unit connecting cables, you may get rid of the user interface assembly.

Be aware: Be sure that you can pull out and push into your IO board sockets vertically when pulling out and assembling the IO board assembly to the situation in the handle. Clear away panhead screws with washers M3X6 (four) Dp50rb login used to secure the IO board, and then you could possibly just take out the IO board. Webpage 116 Take away panhead screws with washers (two M3X6) that are fixed on the primary unit, take out the higher baffle and after that pull out two cables connecting the primary board to the power module assembly.